page_banner

Products

100W Single Output DIN Rail Power Supply MDR-100 Series

Short Description:

Universal AC input/ full range

Protections: Short circuit/ Over load/ Over voltage/ Over temperature

Cooling by free air convection

Can be installed on DIN rail TS-35/7.5 or 15

DC OK relay contact

LED indicator for power on

100% full load burn-in test

No load power consumption<1W

2 years warranty


Product Detail

Product Tags

Product Features

100W Single Output Industrial DIN Rail Power Supply MDR-100 series

Universal AC input/ full range

Protections: Short circuit/ Over load/ Over voltage/ Over temperature

Cooling by free air convection

Can be installed on DIN rail TS-35/7.5 or 15

DC OK relay contact

LED indicator for power on

100% full load burn-in test

No load power consumption<1W

2 years warranty 

Specifications

SPECIFICATIONS
OUTPUT  
Model MDR-100-12 MDR-100-24 MDR-100-48
DC Voltage 12V 24V 48V
Rated Current 7.5A 4A 2A
Current Range 0-7.5A 0-4A 0-2A
Rated Power 90W 96W 96W
Ripple & Noise 120mVp-p 120mVp-p 150mVp-p
Voltage Adj. Range 12-15V 24-30V 48-56V
Voltage Tolerance ±1% ±1% ±1%
Line regulation ±1% ±1% ±1%
Load regulation ±1% ±1% ±1%
Setup, Rise Time 3000ms,50ms/230VAC   3000ms,50ms/115VAC at full load
Hold Up Time 50ms/230VAC   20ms/115VAC at full load
INPUT  
Voltage Range 85~264VAC   47~63 Hz; 120~370VDC
AC Current 1.3A/115VAC   0.8A/230VAC
Efficiency 83% 86% 87%
Inrush Current Cold start 30A/115VAC   60A/230VAC
Leakage Current <1mA/240VAC
PROTECTION  
Over Load 105%~150% rated output power
Protection type: Constant current limiting, recovers automatically after fault condition is removed
Over Voltage 15.6-18V 31.2-36V 57.6-64.8V
Protection type: Shut down o/p voltage, re-power on to recover
Over Temp. Protection type: Shut down o/p voltage, recovers automatically or re-power on recover
Function  
DC OK signal Relay contact rating(max):30V/1A resistive
ENVIRONMENT  
Working Temp., Humidity -10℃~+60℃; 20%~90% RH non-condensing
Storage Temp., Humidity -40℃~+85℃; 10%~95%RH
Temp. Coefficient ±0.03%/℃(0~50℃)
Vibration 10~500Hz, 2G 10min./1cycle, 60min, each along X, Y, Z axes
SAFETY  
Withstand Voltage I/P-O/P: 3KVAC   I/P-FG:2KVAC   O/P-FG:0.5KVAC
Isolation Resistance I/P-O/P, I/P-FG, O/P-F/G: >100M Ohms / 500VDC/25℃/70% RH
STANDARD  
Safety Standard Design refer to UL508, TUV EN60950-1
EMC Standard EN61240-3,EN55011,EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11,EN55024,EN61000-6-2, EN61204-3,heavy industry level, criteria A
OTHERS  
Dimension 55*90*100mm(W*H*D)
Weight 0.42Kg
Packing 30pcs/13.6Kg/0.82CUFT
NOTE  
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2.Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1μf & 47μf parallel capacitor.
3.Tolerance: includes set up tolerance, line regulation and load regulation.
4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
MDR-100-24 (1)
MDR-100-24 (2)
MDR-100-24 (3)
MDR-100-24 (4)
MDR-100-24 (5)
MDR-100-24 (6)
MDR-100-24 (7)
MDR-100-24 (8)
MDR-100-24 (9)
MDR-100-24 (10)
MDR-100-24 (11)
MDR-100-24 (12)

  • Previous:
  • Next:

  • Write your message here and send it to us