100W Single Output Switching Power Supply LRS-100 series

Short Description:

Universal AC input/ full range

Withstand 300VAC surge input for 5 second

Protections: Short circuit / Overload / Over voltage

Cooling by free air convection

LED indicator for power on

100% full load burn-in test

High operating temperature up to 70℃

High efficiency, long life and high reliability

2 years warranty


Product Detail

Product Tags

Features

100W Single Output Switching Power Supply LRS-100 series

AC input range selectable by switch
Withstand 300VAC surge input for 5 second
Protections: Short circuit / Overload / Over voltage/ Over temperature
Cooling by free air convection
LED indicator for power on
100% full load burn-in test
High operating temperature up to 70ºC
High efficiency, long life and high reliability
2 years warranty
more efficient, more thinner, less no-load consumption than old series
Universal AC input/ full range

 

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.

Specifications

SPECIFICATION  
OUTPUT  
Model LRS-100-3.3 LRS-100-5 LRS-100-12 LRS-100-15 LRS-100-24 LRS-100-36 LRS-100-48
DC Voltage 3.3V 5V 12V 15V 24V 36V 48V
Rated Current 20A 18A 8.5A 7A 4.5A 2.8A 2.3A
Current Range 0~20A 0~18A 0~8.5A 0~7A 0~4.5A 0~2.8A 0~2.3A
Rated Power 66W 90W 102W 105W 108W 100.8W 110.4W
Ripple & Noise 100mVp-p 100mVp-p 120mVp-p 120mVp-p 150mVp-p 200mVp-p 200mVp-p
Voltage Adj. Range 2.97~3.6V 4.5 ~ 5.5V 10.2~ 13.8V 13.5~18V 21.6~28.8V 32.4~39.6V 43.2~52.8V
Voltage Tolerance ±3.0% ±2.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
Line Regulation ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
Load Regulation ±2.0% ±1.0% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
Setup, Rise Time 500ms, 30ms/230VAC   500ms, 30ms/115VAC at full load
Hold Up Time 55ms/230VAC   10ms/115VAC at full load
INPUT  
Voltage Range 85 ~ 264VAC    120 ~ 373VDC
Frequency Range 47 ~ 63Hz
Efficiency 84.50% 86% 88% 88.50% 90% 90.50% 91%
AC Current 1.9A/115VAC  1.2A/230VAC
Inrush Current Cold start 50A/230VAC
Leakage Current <0.75mA / 240VAC
PROTECTION  
Over Load 110 ~ 150% rated output power
Protection type: Hiccup mode, recovers automatically after fault condition is removed
Over Voltage 3.8~4.45V 5.75~6.75V 13.8 ~ 16.2V 18.75~21.75V 28.8 ~ 33.6V 41.4~48.6V 55.2~ 64.8V
Protection type: shut down o/p voltage, re-power on to recover
ENVIRONMENT  
Working Temp. -30 ~ +70℃ (Refer to “derating curve”)
Working Humidity 20 ~ 90% RH non-condensing
Storage Temp., Humidity -40 ~ +85℃, 10 ~ 95% RH
Temp. Coefficient ±0.03%/℃ (0 ~ 50℃)
Vibration 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC  
Safety Standards UL60950-1, TUV EN60950-1, EN60335-1/-2-16, CCC GB4943 approved
Withstand Voltage I/P-O/P:3.75KVAC   I/P-FG:2KVAC   O/P-FG:1.25KVAC
Isolation Resistance I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃ / 70% RH
EMC Emission Compliance to EN55022(CISPR22), GB9254 CLASS B, EN55014 EN 61000-3-2,-3
EMC Immunity Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2(EN50082-2), heavy industry level, criteria A
OTHERS  
Dimension 129*97*30mm (L*W*H)
Weight 0.34Kg
Packing 40pcs/carton/14.6kg/0.92CUFT
NOTE  
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance: includes set up tolerance, line regulation and load regulation.4. Line regulation is measured from low line to high line at rated load.

5. Load regulation is measured from 0% to 100% rated load.

6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.

7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.

LRS-100-12 (1)
LRS-100-12 (2)
LRS-100-12 (3)
LRS-100-12 (4)
LRS-100-12 (5)
LRS-100-12 (6)
LRS-100-12 (7)
LRS-100-12 (8)
LRS-100-12 (9)
LRS-100-12 (10)
LRS-100-12 (11)
LRS-100-12 (12)
LRS-100-12 (13)
LRS-100-12 (14)