Note on the use of waterproof power supply:
1. The input voltage of the waterproof switching power supply should be selected according to the design of the circuit. Generally, there are two kinds of input voltage: 220 volts and 110 volts. If you choose improperly, it will damage the switching power supply.
2. Do not connect the ground wire and neutral wire end of the output voltage wiring wrongly, and make sure that the grounding is reliable.
3. After the switching power supply is installed, it is necessary to conduct a power-on trial operation, check the condition of each part, and ensure that it can be powered on after it is normal.
Finally, pay attention to the heat dissipation of the waterproof switching power supply. It is best to install the switching power supply in a position with good air convection conditions, so that the heat can be easily dissipated.
100W Waterproof Single Output Switching Power Supply LPV-100 series
Constant voltage design
Universal AC input/Full range
Withstand 300VAC surge input for 5 seconds
Protections: short circuit/ over load/ over voltage
Cooling by free air convection
Small and compact size
Fully encapsulated with IP67 level
Fully isolated plastic case
Suitable for LED lighting and moving sign applications
100% full load burn-in test
Low cost, high reliability
2 year warranty
SPECIFICATIONS | ||||||
OUTPUT | ||||||
Model | LPV-100-5 | LPV-100-12 | LPV-100-15 | LPV-100-24 | LPV-100-36 | LPV-100-48 |
DC Voltage | 5V | 12V | 15V | 24V | 36V | 48V |
Rated Current | 12A | 8.5A | 6.7A | 4.2A | 2.8A | 2.1A |
Current Range | 0-12A | 0-8.5A | 0-6.7A | 0-4.2A | 0-2.8A | 0-2.1A |
Rated Power | 60W | 102W | 100.5W | 100.8W | 100.8W | 100.8W |
Ripple & Noise | 80mVp-p | 120mVp-p | 120mVp-p | 150mVp-p | 150mVp-p | 150mVp-p |
Voltage Tolerance | ±8% | ±5% | ||||
Line Regulation | ±1% | |||||
Load Regulation | ±6% | ±2% | ||||
Setup, Rise Time | 2000ms, 25ms/230VAC 2000ms, 25ms/115VAC | |||||
Hold Up Time | 50ms/230VAC 14ms/115VAC at full load | |||||
INPUT | ||||||
Voltage Range | 90~264VAC 47-63Hz; 127~370VDC | |||||
AC Current | 2.2A/115V 1.2A/230V | |||||
Efficiency | 80% | 85% | 87% | 88% | 88% | 89% |
Inrush Current | Cold Start 75A at 230VAC | |||||
Leakage Current | 0.25mA/240VAC | |||||
PROTECTION | ||||||
Over Load | 110-150% rated output power | |||||
Protection type: Hiccup mode, recovers automatically after fault condition is removed | ||||||
Over Voltage | 5.75-6.75V | 13.8-16.2V | 17.25-20.25V | 27.6-32.4V | 41.4-48.6V | 55.2-64.8V |
Protection type: Shut down o/p voltage, re-power on to recover | ||||||
ENVIRONMENT | ||||||
Working Temp.Humidity | -25 ~ +70℃ (Refer to “Derating Curve”) 20-90% RH non-condensing | |||||
Storage Temp.Humidity | -40℃~+80℃; 10%~95%RH | |||||
Temp.Coefficient | ±0.03%/℃(0~50℃) | |||||
Vibration | 10~500Hz,2G 10min,/1cycle,period for 60min,each along X,Y,Z axes | |||||
SAFETY | ||||||
Withstand Voltage | I/P-O/P:3KVAC | |||||
Isolation Resistance | I/P-O/P>100M Ohms / 500VDC / 25℃ / 70% RH | |||||
STANDARD | ||||||
Safety Standard | UL8750, CSA C22.2 No.250.13-12, UL879,CSA C22.2 No.207-M89, IP67 approved, design refer to EN60950-1 | |||||
EMC Standard | EN61000-4-2,3,4,5,6,8,11,EN55024,light industry level, criteria A | |||||
OTHERS | ||||||
Dimension | 190*52*37mm(L*W*H) | |||||
Weight | 0.63kg;20pcs/13.6kg/0.55CUFT | |||||
NOTE | ||||||
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. | ||||||
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. | ||||||
3. Tolerance: includes set up tolerance, line regulation and load regulation. | ||||||
4. Derating may not be needed under low input voltage. Please check the static characteristics for more details. |