In the process of using the waterproof switching power supply, the first thing that engineers need to pay attention to is the self-temperature rise of the switching power supply. Normally, the temperature rise of the better power equipment depicted by the power supply will be kept at about 25-30°C, while the temperature rise of the poorer depicted will be greater than 35°C. The switching power supply used in public lighting and outdoor lighting places needs to be waterproof, and a sealed enclosure is required. In order to improve the protection level, the manufacturer needs to fill the glue. The price of different colloidal materials is different, and the heat conduction function is also different, which is cheap. Selling glue has poor thermal conductivity and requires high-temperature baking, which often results in invisible damage and tight strains of different degrees of equipment, leaving danger.
The self-temperature rise of lamps and lanterns is also a big problem that needs to be paid attention to when the waterproof switching power supply is used in public lighting, because a lot of heat generated depends on the shell to dissipate heat. It is reasonable to describe the lamp. The temperature of the shell itself is about Between 20℃-25℃. That is to say, it is normal for the lamp housing temperature to be about 45°C-50°C under the operating condition of room temperature 25°C. If it exceeds the range of this index, it means that the product has defects in temperature rise.
150W Single Output Waterproof Switching Power Supply LDV-150 series
High efficiency, High reliability, Low cost
Protections: Short circuit/Over load/Over voltage/High temperature
Waterproof grade: IP67
Suitable for LED lighten and moving sign applications.
2 years warranty
SPECIFICATION | ||
OUTPUT | ||
Model | LDV-150-12 | LDV-150-24 |
DC Voltage | 12V | 24V |
Rated Current | 12.5A | 6.25A |
Current Range | 0-12.5A | 0-6.25A |
Rated Power | 150W | 150W |
Ripple & Noise | 120mVp-p | 120mVp-p |
Voltage Adj. Range | ±10% | ±10% |
Voltage Tolerance | ±1% | ±1% |
Inlet Stability | ±0.5% | ±0.5% |
Load Stability | ±0.5% | ±0.5% |
Setup, Rise, Hold Up Time | 800s,50ms,10ms/115VAC 300ms,50ms,80ms/230VAC | |
INPUT | ||
Voltage Range | 176~264VAC | |
AC Current | 2.5A/115V 1.5A/230V | |
Efficiency | 79% | |
Inrush Current | Cold-start current 30A/115V 60A/230V | |
PROTECTION | ||
Over Load | 105%~150% | |
plusing hiccup shutdown Reset:auto recovery | ||
ENVIRONMENT | ||
Working Temp., Humidity | -10℃~+60℃(Refer to output derating curve),20%~90%RH | |
Storage Temp., Humidity | -20℃~+85℃, 10%~95%RH | |
Temp. Coefficient | ±0.03%/℃(0-50℃) | |
Vibration | 10-500Hz,2G 10min,/1cycle,Period for 60min,Each axes | |
SAFETY | ||
Withstand Voltage | I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC | |
Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC | |
STANDARD | ||
Safety Standard | UL1012TUV EN60950(IEC950,UL1950) ApprovedIP67 | |
EMC Standard | CLSPR22(EN55022),IEC801-2,3,4,IEC555-2 Verification | |
OTHERS | ||
Dimension | 220*69*42mm(L*W*H) | |
Weight | 1.2Kg |