page_banner

Products

155W Single Output with Battery Charger (UPS Function) AD-155 series

Short Description:

Universal AC input / Full range

Protections: Short circuit / Overload / Over voltage

Battery low and battery polarity protection

Cooling by free air convection

100% full load burn-in test

Fixed switching frequency at PFC 67KHz, PWM 134KHz

2 years warranty


Product Detail

Product Tags

Features

155W Single Output with Battery Charger (UPS Function) AD-155 series 

Universal AC input / Full range

Protections: Short circuit / Overload / Over voltage

Battery low and battery polarity protection

Cooling by free air convection

100% full load burn-in test

Fixed switching frequency at PFC 67KHz, PWM 134KHz

2 years warranty


Single Output power supply with UPS(Uninterrupted) function.

This type of power supply can function as usual in emergency situations such as power outages.

It can provide a continuous, stable, uninterrupted power supply.The principle is relatively complex, the input and output are AC AC-AC (including AC-DC, DC-DC, DC-AC).The function focuses on keeping the output power supply stable, at the same time to ensure that the input is abnormal can still continue to uninterrupted power supply, with high reliability and high anti-interference.

We have designed LED director to show the power ON/OFF and all kinds of protections,you can rest assured when use it.You can use this kind of products in many situations when you need battery charge.

We also provide 2 years warranty,this is our guarantee for product quality.We promise to provide our technical support wholeheartedly.You can always trust a mature technical team.
LEYU electric products,your cost-effective choice.ous.

UPS power function function

As computer application systems have higher and higher requirements for power supply, UPS has been paid more and more attention, and has gradually developed into a kind of functions such as voltage stabilization, frequency stabilization, filtering, anti-electromagnetic and radio frequency interference, and anti-voltage surfing. Power protection system.

Especially when the line and power supply quality of the power grid is not too high, the anti-interference technology is backward, and the computer system has relatively high requirements for the power supply, the role of UPS becomes more obvious.

Specifications

SPECIFICATION

MODEL

AD-155A

AD-155B

AD-155C

OUTPUT

 

 

 

Output number

CH1

CH2

CH1

CH2

CH1

CH2

DC voltage

13.8V

13.3V

27.6V

27.1V

54V

53.5V

Rated Current

10.5A

0.5A

5A

0.5A

2.7A

0.2A

Current Range

0~11.5A

0-0.5A

0~5.5A

0-0.5A

0-2.7A

0-0.5A

Rated Power

151.55W

151.55W

156.5W

Ripple & Noise

150mVp-p

--------

150mVp-p

--------

240mVp-p

--------

Voltage Adj. Range

CH1:12~14.5V

CH1:24~29V

CH1:48-58V

Voltage Tolerance

±2.0%

--------

±1.0%

--------

±1.0%

--------

Line Regulation

±0.5%

--------

±0.5%

--------

±0.5%

--------

Load Regulation

±0.5%

--------

±0.5%

--------

±0.5%

--------

Setup, Rise Time

1000ms, 90ms/230VAC          2000ms, 90ms/115VAC at full load

Hold Up Time

24ms/230VAC          20ms/115VAC at full load

INPUT

 

Voltage Range

88~264VAC   47~63Hz; 124~370VDC

AC Current

2.5A/115VAC          1.5A/230VAC

Efficiency

80%

84%

84%

Inrush Current

Cold start 20A/115VAC   40A/230VAC

Leakage Current

<1mA /240VAC

PROTECTION

 

Over Load

CH1:105 ~ 135%          CH2:0.51 ~ 0.9A rated output power

Protection type: AC Charging Mode: Hiccup mode, recovers automatically after fault condition is removed UPS Mode: Protected by internal fuse

Over Voltage

CH1:15.87~18.63V

CH1:31.74~37.26V

CH1:62.1 ~ 72.9V

Protection type:Shut down o/p voltage, re-power on to recover

Battery Low

10V±0.8V

19.5V(+1.5V,-1V )

39V±2V

ENVIRONMENT

 

Working Temp.

-10~+60℃ (Refer to “Derating Curve”)

Working Humidity

20~90%RH non-condensing

Storage Temp., Humidity

-20~+85℃,10~95%RH

Temp. Coefficient

±0.03%/ ℃(0~50℃ )

Vibration

10~500Hz,2G10min./1cycle,60min.each along X, Y,Z axes

SAFETY &EMC

 

Safety Standards

UL60950-1, TUV EN60950-1

Withstand Voltage

I/P-O/P:3KVAC   I/P-FG:1.5KVAC   O/P-FG:0.5KVAC

Isolation Resistance

I/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC /25℃ /70%RH

EMC Emission

Compliance to EN55022(CISPR22) Class B, EN61000-3-2,-3

EMC Immunity

Compliance to EN61000-4-2,3,4,5,6,8,11,EN55024,light industry level, criteria A

OTHERS

 

Dimension

199*110*50mm (L*W*H)

Weight

0.88Kg

Packing

16pcs/carton/15kg/0.95CUFT

NOTE

 

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance: includes set up tolerance, line regulation and load regulation.

4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.

1 (1)
1 (2)
1 (3)
1 (4)
1 (5)
1 (6)
1 (7)
1 (8)
1 (9)