1. The input voltage of the waterproof switching power supply should be selected according to the design of the circuit. Generally, there are two kinds of input voltage: 220 volts and 110 volts. If you choose improperly, it will damage the switching power supply.
2. Do not connect the ground wire and neutral wire end of the output voltage wiring wrongly, and make sure that the grounding is reliable.
3. After the switching power supply is installed, it is necessary to conduct a power-on trial operation, check the condition of each part, and ensure that it can be powered on after it is normal.
Finally, pay attention to the heat dissipation of the waterproof switching power supply. It is best to install the switching power supply in a position with good air convection conditions, so that the heat can be easily dissipated.
200W Single Output Waterproof Switching Power Supply LDV-200 series
High efficiency, High reliability, Low cost
Protections: Short circuit/Over load/Over voltage/High temperature
Waterproof grade: IP67
Working Frequency: 65 KHz
Suitable for LED lighten and moving sign applications.
2 years warranty
SPECIFICATION | |||
OUTPUT | |||
Model | LDV-200-12 | LDV-200-24 | LDV-200-36 |
DC Voltage | 12V | 24V | 36V |
Rated Current | 16.5A | 8.3A | 5.5A |
Current Range | 0-16.5A | 0-8.3A | 0-5.5A |
Rated Power | 198W | 199W | 198W |
Ripple & Noise | 150mVp-p | 200mVp-p | 200mVp-p |
Voltage Tolerance | ±1% | ±1% | ±1% |
Inlet Stability | ±0.5% | ±0.5% | ±0.5% |
Load Stability | ±0.5% | ±0.5% | ±0.5% |
Setup, Rise, Hold Up Time | 200ms,20ms,30ms/230VAC | ||
INPUT | |||
Voltage Range | 180~264 VAC 47~63Hz;255~373VDC | ||
AC Current | 1.5A/230VAC | ||
Efficiency | 82% | 84% | 85% |
Inrush Current | Cold-start current 40A/230VAC | ||
PROTECTION | |||
Over Load | 105%~135% | ||
Protection:Hiccup mode, recovers automatically after fault condition is removed | |||
Over Voltage | 30~32V | 42~44V | |
Protection:Hiccup mode, recovers automatically after fault condition is removed | |||
High Tem. | ≥85℃ | ||
Protection:cut off the output, recovers automatically after fault condition is removed | |||
ENVIRONMENT | |||
Working Temp., Humidity | -10℃~+60℃,20%~90%RH | ||
Storage Temp., Humidity | -20℃~+85℃, 10%~95%RH | ||
Temp. Coefficient | ±0.03%/℃(0-50℃) | ||
Vibration | 10-500Hz,2G 10min,/1cycle,Period for 60min,Each axes | ||
SAFETY | |||
Withstand Voltage | I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC | ||
Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC | ||
STANDARD | |||
Safety Standard | EN61347-1 EN61347-2-13 IP67 | ||
EMC Standard | EN55015 EN61547 EN61000-3.4 CLASSB | ||
OTHERS | |||
Dimension | 215*69*43(L*W*H) | ||
Weight | 1.3Kg | ||
NOTE
|
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. | ||
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. | |||
3. Tolerance: includes set up tolerance, line regulation and load regulation. |