Features

20W Single Output Industrial DIN Rail Power Supply MDR-20 series

Universal AC input/ full range

Protections: Short circuit/ Over load/ Over voltage

Cooling by free air convection

Can be installed on DIN rail TS-35/7.5 or 15  

LED indicator for power on

100% full load burn-in test

2 years warranty 

Specifications

SPECIFICATIONS
OUTPUT  
Model MDR-20-5 MDR-20-12 MDR-20-15 MDR-20-24
DC Voltage 5V 12V 15V 24V
Rated Current 3A 1.67A 1.34A 1A
Current Range 0-3A 0-1.67A 0-1.34A 0-1A
Rated Power 15W 20W 20W 24W
Ripple & Noise 80mVp-p 120mVp-p 120mVp-p 150mVp-p
Voltage Tolerance ±2% ±1% ±1% ±1%
Line regulation  ±1.0% ±1.0% ±1.0% ±1.0%
Load regulation ±1.0% ±1.0% ±1.0% ±1.0%
Setup, Rise Time 500ms,30ms/230VAC   1000ms,30ms/115VAC at full load
Hold Up Time 50ms/230VAC   25ms/115VAC at full load
INPUT  
Voltage Range 85~264VAC   47~63Hz; 120~370VDC
AC Current 0.55A/115VAC   0.35A/ 230VAC
Efficiency 76% 80% 81% 84%
Inrush Current Cold start 20A/115V   40A/230V
Leakage Current <1mA/240VAC
PROTECTION  
Over Load 105% ~ 160% rated output power
Protection type: Constant current limiting, recovers automatically after fault condition is removed
Over Voltage 5.75-6.75V 13.8-16.2V 17.25-20.25V 27.6-32.4V
Protection type: Shut down o/p voltage, re-power on to recover
ENVIRONMENT  
Working Temp., Humidity -20℃~+70℃; 20%~90% RH non-condensing
Storage Temp., Humidity -40℃~+85℃; 10%~95%RH
Temp. Coefficient ±0.03%/℃(0~50℃)
Vibration 10~500Hz, 2G 10min./1cycle, period for 60min, each along X, Y, Z axes
SAFETY  
Withstand Voltage I/P-O/P: 3KVAC   I/P-FG:2KVAC   O/P-FG:0.5KVAC
Isolation Resistance I/P-O/P, I/P-FG, O/P-F/G: 100M Ohms / 500VDC/25℃/70% RH
STANDARD  
Safety Standard Design refer to UL508,TUV EN60950-1
EMC Standard Design refer to EN55011,EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11,EN55024,EN61000-6-1,EN61204-3, light industry level, criteria A
OTHERS  
Dimension 22.5*90*100mm(W*H*D)
Weight 0.19Kg
Packing 72pcs/carton/14.7kg/0.91CUFT
NOTE  
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2.Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1μf & 47μf parallel capacitor.
3.Tolerance: includes set up tolerance, line regulation and load regulation.
4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
MDR-20-24 (1)
MDR-20-24 (2)
MDR-20-24 (3)
MDR-20-24 (4)
MDR-20-24 (5)
MDR-20-24 (6)
MDR-20-24 (7)
MDR-20-24 (8)
MDR-20-24 (9)
MDR-20-24 (10)
MDR-20-24 (11)
MDR-20-24 (12)

  • Previous:
  • Next:

  • Write your message here and send it to us