page_banner

Products

20W Waterproof Single Output Switching Power Supply LPV-20 series

Short Description:

Constant voltage design

Universal AC input/Full range

Withstand 300VAC surge input for 5 seconds

Protections: short circuit/ over load/ over voltage

Cooling by free air convection

Small and compact size

Fully encapsulated with IP67 level

Fully isolated plastic case

Class II power unit, no FG

Class 2 power unit

Pass LPS

Suitable for LED lighting and moving sign applications

100% full load burn-in test

Low cost, high reliability
2 year warranty


Product Detail

Product Tags

Proper use of waterproof switching power supply

In the process of using the waterproof switching power supply, the first thing that engineers need to pay attention to is the self-temperature rise of the switching power supply. Normally, the temperature rise of the better power equipment depicted by the power supply will be kept at about 25-30°C, while the temperature rise of the poorer depicted will be greater than 35°C. The switching power supply used in public lighting and outdoor lighting places needs to be waterproof, and a sealed enclosure is required. In order to improve the protection level, the manufacturer needs to fill the glue. The price of different colloidal materials is different, and the heat conduction function is also different, which is cheap. Selling glue has poor thermal conductivity and requires high-temperature baking, which often results in invisible damage and tight strains of different degrees of equipment, leaving danger.

The self-temperature rise of lamps and lanterns is also a big problem that needs to be paid attention to when the waterproof switching power supply is used in public lighting, because a lot of heat generated depends on the shell to dissipate heat. It is reasonable to describe the lamp. The temperature of the shell itself is about Between 20℃-25℃. That is to say, it is normal for the lamp housing temperature to be about 45°C-50°C under the operating condition of room temperature 25°C. If it exceeds the range of this index, it means that the product has defects in temperature rise.

One problem that needs to be noted here is that during work, every time the temperature of the electrolytic capacitor of the switching power supply rises by 10°C, the life span will be halved, which will directly affect its service life. At present, related technical personnel in China have proposed whether ceramic or solid capacitors can be used in the lighting field. However, with the current capacitor technology, neither of these two types of capacitors can be made into high-voltage and large-capacity, which is rather regrettable. However, the use of long-life capacitors may not ensure the power life. To increase the power life, improvements need to be made in many ways, such as using capacitors with higher lifespans, increasing power supply power, optimizing power supply heat dissipation, or lighting heat dissipation, and so on.

Features

20W Waterproof Single Output Switching Power Supply LPV-20 series

Constant voltage design

Universal AC input/Full range

Withstand 300VAC surge input for 5 seconds

Protections: short circuit/ over load/ over voltage

Cooling by free air convection

Small and compact size

Fully encapsulated with IP67 level

Fully isolated plastic case

Class II power unit, no FG

Class 2 power unit

Pass LPS

Suitable for LED lighting and moving sign applications

100% full load burn-in test

Low cost, high reliability

2 year warranty

Specifications

SPECIFICATIONS
OUTPUT  
Model

LPV-20-5

LPV-20-12

LPV-20-15

LPV-20-24

DC Voltage

5V

12V

15V

24V

Rated Current

3A

1.67A

1.33A

0.84A

Current Range

0-3A

0-1.67A

0-1.33A

0-0.84A

Rated Power

15W

20W

20W

20.2W

Ripple & Noise

80mVp-p

120mVp-p

120mVp-p

150mVp-p

Voltage Tolerance

±5%

Setup, Rise Time 500ms,20ms/230VAC     500ms,20ms/115VAC at full load
Hold Up Time 50ms/230VAC           16ms/115VAC
INPUT  
Voltage Range 90~264VAC    47~63Hz; 127~370VDC
AC Current 0.55A/115V   0.35A/230V
Efficiency

77%

81%

83%

83%

Inrush Current Cold start 70A/230V
Leakage Current <0.25mA/240VAC
PROTECTION  
Over Load  110%~150% rated power
Protection type: Shut down o/p voltage, recovers automatically after fault condition is removed
Over Voltage 5.75-6.75V 13.8-16V 17.5-21V 28-32V
Protection type:Shut off o/p voltage, clamping by zener diode
ENVIRONMENT  
Working Temp., Humidity -30℃~+70℃; 20%~90%RH non-condensing
Storage Temp., Humidity -40℃~+80℃; 10%~95%RH
Temp. Coefficient ±0.03%/℃(0~50℃)
Vibration 10~500Hz, 2G 10min./1cycle, period for 60min, each along X, Y, Zaxes
SAFETY  
Withstand Voltage I/P-O/P: 3KVAC
Isolation Resistance I/P-O/P>100M Ohms/500VDC25℃/70%RH
STANDARD  
Safety Standard Design refer to UL879, UL1310,CSA C22.2 No.207-M89, CAN/CSA C22.2 No.223-M91,TUV EN60950-1,IP67 Approved
EMC Standard Design refer to EN55022(CISPR22) Class B,EN61000-3-2 Class A, EN61000-3-3
OTHERS  
Dimension 118*35*26mm(L*W*H)
Weight 0.22Kg
Packing 60pcs/14.2Kg/0.0.62CUFT
NOTE  
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.

2.Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1μ & 47μ parallel capacitor.

3.Tolerance: includes set up tolerance, line regulation and load regulation.