Short Description:

Universal AC input/ full range

Built-in active PFC function

Protections: Short circuit/ Over load/ Over voltage/ Over temperature

Cooling by free air convection

Can be installed on DIN rail TS-35/7.5 or 15

LED indicator for power on

100% full load burn-in test

Fixed switching frequency at 100KHz

2 year warranty


Product Detail

Product Tags

Features

240W Single Output Industrial DIN Rail Power Supply        NDR-240 series
Universal AC input/ full range
Built-in active PFC function
Protections: Short circuit/ Over load/ Over voltage/ Over temperature
Cooling by free air convection
Can be installed on DIN rail TS-35/7.5 or 15
LED indicator for power on
100% full load burn-in test
Fixed switching frequency at 100KHz
2 year warranty

Specifications

SPECIFICATIONS
OUTPUT  
Model

NDR-240-24

NDR-240-48

DC Voltage

24V

48V

Rated Current

10A

5A

Current Range

0-10A

0-5A

Rated Power

240W

240W

Ripple & Noise

150mVp-p

150mVp-p

Voltage Adj. Range

24-28V

48-55V

Voltage Tolerance

±1%

±1%

Setup, Rise Time 1500ms,100ms/230VAC   3000ms,100ms/115VAC at full load
Hold Up Time 28ms/230VAC   22ms/115VAC at full load
   
INPUT  
Voltage Range 90~264VAC   47~63Hz; 127~370VDC
AC Current 2.5A/115V   1.3A/230V
Efficiency

84%

85%

Inrush Current Cold start 20A/115V   35A/230V
Leakage Current <1mA/240VAC
   
PROTECTION  
Over Load 105%~130%
Protection type: Constant current limiting, recovers automatically after fault condition is removed
Over Voltage

29-33V

56-65V

Protection type: Shut down o/p voltage, re-power on to recover
Over Temp. 100℃±5℃(TSW1)
Protection type: Shut down o/p voltage, recovers automatically after temperature goes down
   
ENVIRONMENT  
Working Temp., Humidity -10℃~+70℃; 20%~90%RH
Storage Temp., Humidity -20℃~+85℃; 10%~95%RH
Vibration 10~500Hz, 2G 10min./1cycle, period for 60min, each along X, Y, Z axes
   
SAFETY  
Withstand Voltage I/P-O/P: 3KVAC   I/P-FG: 1.5KVAC   O/P-FG: 0.5KVAC
Isolation Resistance I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC
   
STANDARD  
Safety Standard Design refer to UL508,UL60950-1, TUV EN60950-1
EMC Standard EN55011,EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11,ENV50204,EN55024,EN61000-6-2(EN50082-2)
   
OTHERS  
Dimension 125.5*125.2*100mm(L*W*H)
Weight 1.3Kg
Packing 12pcs/15.5Kg/1.2CUFT
   
NOTE  
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1μ & 47μ parallel capacitor.

3 .Tolerance: includes set up tolerance, line regulation and load regulation.

4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.

5 . Derating may be needed under low input voltages. Please check the derating curve for more details.