page_banner

Products

45W Single Output Industrial DIN Rail Power Supply DR-45 series

Short Description:

Universal AC input/ full range

Protections: Short circuit/Over load/Over voltage/Over temperature

Cooling by free air convection

Can be installed on DIN rail TS-35/7.5 or 15

LED indicator for power on

100% full load burn-in test

Fixed switching frequency at 100KHz

2 years warranty


Product Detail

Product Tags

Proper use of guide rail power supply

1. The AC voltage specification used by the rail power supply is 110VAC 220VAC 380VAC. Before powering on the power supply, check whether the connected voltage matches the power supply input voltage.

2. Do not connect the load before powering on for the first time, first check whether the output voltage of the power supply is consistent with the power supply of the connected equipment, so as not to damage the connected equipment.

3 The ground wire must be connected before the power supply is used. The ground wire of this type of power supply is at the position marked in the figure.

4. The power supply should be placed in a well-ventilated center.

5 The output current of the rail power supply is definitely determined; it is affirmed according to the rated standard current of the equipment supplied by the rail power supply or the uniform current value measured by a multimeter. When the ambient temperature is high, the air activity is not good, and the load is rational, an additional current margin of 20-30% should be prepared.

6 The input power of the rail power supply is determined: the rated input power of the rail power supply depends on the rated power of the supplied equipment. Under the condition of not knowing the rated power of the equipment supplied, it can be obtained based on the product value of the rated current and voltage of the equipment supplied (current X voltage = power). When the user selects the power supply, it should be greater than 15-30% of the practical power and peak power.

7 The number of DC output of the rail power supply is determined: the rail power supply normally has up to four outputs. (S-single group, D-double group, T-three group, Q-four group) According to the equipment provided.

8 The rail power supply has maintenance functions such as over/under voltage, over current, overheating maintenance and fan heat dissipation. Please stop the selection based on the actual application status to strengthen the stability and reliability of the system engineering.

9 The types of rail power supplies are: industrial iron shell type, rail type, LED outdoor rainproof and waterproof type, etc. Please choose according to practical application.

Features

45W Single Output Industrial DIN Rail Power Supply DR-45 series

Universal AC input/ full range

Protections: Short circuit/Over load/Over voltage/Over temperature

Cooling by free air convection

Can be installed on DIN rail TS-35/7.5 or 15

LED indicator for power on

100% full load burn-in test

Fixed switching frequency at 100KHz

2 years warranty 

Specifications

SPECIFICATIONS
OUTPUT  
Model

DR-45-5

DR-45-12

DR-45-15

DR-45-24

DC Voltage

5V

12V

15V

24V

Rated Current

5A

3.5A

2.8A

2A

Current Range

0-5A

0-3.5A

0-2.8A

0-2A

Rated Power

25W

42W

42W

48W

Ripple & Noise

100mVp-p

200mVp-p

240mVp-p

480mVp-p

Voltage Adj. Range

4.75-5.5V

10.8-13.2V

13.5-16.5V

21.6-26.4V

Voltage Tolerance

±2%

±1%

±1%

±1%

Line regulation

±1%

±1%

±1%

±1%

Load regulation

±1%

±1%

±1%

±1%

Setup, Rise, Hold Up Time 800ms, 60ms/230VAC at full load

60ms/230VAC at full load

INPUT  
Voltage Range 85~264VAC   47~63Hz; 120~370VDC
AC Current 1.5A/115V   0.75A/230V
Efficiency

72%

77%

77%

80%

Inrush Current Cold start 28A/115VAC   56A/230VAC
Leakage Current <1mA/240VAC
PROTECTION  
Over Load 105%~150% rated output power
Protection type: Constant current limiting, recovers automatically after fault condition is removed
Over Voltage 5.75-6.75VAC 13.8-16.2VAC 17.25-20.25VAC 27.6-32.4VAC
Protection type: Shut off o/p voltage, clamping by zener diode
Over Temp.. Tj 135℃ typically (U1) Detect on heat sink of power transistor
Protection type: Shut down o/p voltage, re-power on to recover
ENVIRONMENT  
Working Temp., Humidity -10℃~+50℃; 20%~90%RH non-condensing
Storage Temp., Humidity -20℃~+85℃; 10%~95%RH
Temp. Coefficient ±0.03%/℃(0~50℃)
Vibration 10~500Hz, 2G 10min./1cycle, period for 60min, each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
SAFETY  
Withstand Voltage I/P-O/P: 3KVAC   I/P-FG: 1.5KVAC   O/P-FG: 0.5KVAC
Isolation Resistance I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC/20℃/70%RH
STANDARD  
Safety Standard Design refer to UL508,TUV EN60950-1
EMC Standard Design refer to EN55011,EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11,EN55024,EN61000-6-2(EN50082-2),heavy industry level, criteria A
OTHERS  
Dimension 93*78*67mm (L*W*H)
Weight 0.31Kg
Packing 48pcs/17.5Kg/1.3CUFT
NOTE  
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1μ & 47μ parallel capacitor.

3. Tolerance: includes set up tolerance, line regulation and load regulation.

4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.

DR-45-12 (1)
DR-45-12 (2)
DR-45-12 (3)
DR-45-12 (4)
DR-45-12 (5)
DR-45-12 (6)
DR-45-12 (7)
DR-45-12 (8)
DR-45-12 (9)
DR-45-12 (10)
DR-45-12 (11)
DR-45-12 (12)

  • Previous:
  • Next:

  • Write your message here and send it to us