The generator can convert mechanical energy into electrical energy, and the dry battery can convert chemical energy into electrical energy. The generator and battery themselves are not charged, and their two poles have positive and negative charges respectively.
Voltage is generated by positive and negative charges (current is formed by the directional movement of charges under the action of voltage), which is inherent in the charge conductor. To generate current, only voltage is required. When the battery poles are connected to the conductors, in order to generate current And when the positive and negative charges are released, when the charge is exhausted, the charge is exhausted (squeezed).
As computer application systems have higher and higher requirements for power supply, UPS has been paid more and more attention, and has gradually developed into a kind of functions such as voltage stabilization, frequency stabilization, filtering, anti-electromagnetic and radio frequency interference, and anti-voltage surfing. Power protection system.
Especially when the line and power supply quality of the power grid is not too high, the anti-interference technology is backward, and the computer system has relatively high requirements for the power supply, the role of UPS becomes more obvious.
55W Dual Output with Battery Charger (UPS Function) ADD-55 series
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage
Battery low protections
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 45 KHz
2 years warranty
SPECIFICATION | ||||||
MODEL | ADD-55A | ADD-55B | ||||
OUTPUT | ||||||
Output number | CH1 | CH2 | CH3 | CH1 | CH2 | CH3 |
DC voltage | 13.8V | 5V | 13.4V | 27.6V | 5V | 26.5V |
Rated Current | 2.5A | 3A | 0.23A | 1.3A | 3A | 0.16A |
Current Range | 0~3.5A | 0~4A | -------- | 0~2A | 0~4A | -------- |
Rated Power | 52.58W | 55.12W | ||||
Ripple & Noise | 100mVp-p | 100mVp-p | -------- | 150mVp-p | 150mVp-p | -------- |
Voltage Adj. Range | CH1:12~14.5V | CH1:24~29V | ||||
Voltage Tolerance | ±1.0% | ±3.0% | -------- | ±1.0% | ±3.0% | -------- |
Line Regulation | ±1.0% | ±0.5% | -------- | ±1.0% | ±0.5% | -------- |
Load Regulation | ±1.0% | ±0.5% | -------- | ±1.0% | ±0.5% | -------- |
Setup, Rise Time | 800ms,50ms/230VAC 1600ms,50ms/115VAC at full load | |||||
Hold Up Time | 80ms/230VAC 16ms/115VAC at full load | |||||
INPUT | ||||||
Voltage Range | 88~264VAC 47~63Hz; 124~370VDC | |||||
AC Current | 1.6A/115VAC 1A/230VAC | |||||
Efficiency | 71% | 74% | ||||
Inrush Current | Cold start 20A/115VAC 40A/230VAC | |||||
Leakage Current | <1mA /240VAC | |||||
PROTECTION | ||||||
Over Load | 105~150% rated output power | |||||
Protection type: AC Charging Mode: Hiccup mode, recovers automatically after fault condition is removed UPS Mode: Protected by internal fuse | ||||||
Over Voltage | CH1:14.49~18.63V | CH2:28.98~37.26V | ||||
Protection type: Hiccup mode, recovers automatically after fault condition is removed | ||||||
Battery Low | 9.5~11V | 20~22V | ||||
ENVIRONMENT | ||||||
Working Temp. | -10~+60℃ (Refer to “Derating Curve”) | |||||
Working Humidity | 20~90%RH non-condensing | |||||
Storage Temp., Humidity | -20~+85℃,10~95%RH | |||||
Temp. Coefficient | ±0.03%/ ℃(0~50℃ )on CH1 output | |||||
Vibration | 10~500Hz,2G10min./1cycle,60min.each along X, Y,Z axes | |||||
SAFETY &EMC | ||||||
Safety Standards | Design refer to UL60950-1, TUV EN60950-1 | |||||
Withstand Voltage | I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |||||
Isolation Resistance | I/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC /25℃ /70%RH | |||||
EMC Emission | Compliance to EN55022(CISPR22) Class B, EN61000-3-2,-3 | |||||
EMC Immunity | Compliance to EN61000-4-2,3,4,5,6,8,11,EN55024,light industry level, criteria A | |||||
OTHERS | ||||||
Dimension | 159*97*38mm(L*W*H) | |||||
Weight | 0.57Kg | |||||
Packing | 24pcs/13.7Kg/0.75CUFT | |||||
NOTE | ||||||
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. | ||||||
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. | ||||||
3. Tolerance: includes set up tolerance, line regulation and load regulation. | ||||||
4. The power supply is considered a component which will be installed into final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |