page_banner

Products

75W Single Output Industrial DIN Rail Power Supply NDR-75 series

Short Description:

Universal AC input / Full range

Protections: Short circuit / Overload / Over voltage/ Over temperature

Cooling by free air convection

Can be installed on DlN rail TS-35/7.5 or 15

UL 508 (industrial control equipment} approved

EN61000-6-2(EN50082-2} industrial immunity level

100% full load burn-in test

3 years warranty


Product Detail

Product Tags

Features

75W Single Output Industrial DIN Rail Power Supply         NDR-75 series

Universal AC input / Full range

Protections: Short circuit / Overload / Over voltage/ Over temperature

Cooling by free air convection

Can be installed on DlN rail TS-35/7.5 or 15

UL 508 (industrial control equipment} approved

EN61000-6-2(EN50082-2} industrial immunity level

100% full load burn-in test

3 years warranty

Specifications

MODEL

NDR-75-12

NDR-75-24

NDR-75-48

DC VOLTAGE

12V

24V

48V

RATED CURRENT

6.3A

3.2A

1.6A

CURRENT RANGE

0 ~ 6.3A

0 ~ 3.2A

0 ~ 1.6A

RATED POWER

75.6W

76.8W

76.8W

RIPPLE & NOISE (max.) Note.2

80mVp-p

120mVp-p

150mVp-p

VOLTAGE ADJ. RANGE

12 ~ 14V

24 ~ 28V

48 ~ 55V

VOLTAGE TOLERANCE Note.3

±2.0%

±1.0%

±1.0%

LINE REGULATION

±0.5%

±0.5%

±0.5%

LOAD REGULATION

±1.0%

±1.0%

±1.0%

SETUP, RISE TIME 1200ms, 60ms/230VAC 2000ms, 60ms/115VAC at full load
HOLD UP TIME (Typ.) 60ms/230VAC 12ms/115VAC at full load
VOLTAGE RANGE Note.6 90 ~ 264VAC 127 ~ 370VDC [DC input operation possible by connecting AC/L(+), AC/N(-)]
FREQUENCY RANGE 47 ~ 63Hz
EFFICIENCY (Typ.)

85.50%

88%

89%

AC CURRENT (Typ.) 1.45A/115VAC 0.9A/230VAC
INRUSH CURRENT (Typ.) 20A/115VAC 35A/230VAC
LEAKAGE CURRENT <1mA / 240VAC
OVERLOAD 105 ~ 130% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE

14 ~ 17V

29 ~ 33V

56 ~ 65V

Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE Protection type : Shut down o/p voltage, re-power on to recover
WORKING TEMP. -20 ~ +70℃ (Refer to "Derating Curve")
WORKING HUMIDITY 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT ±0.03%/℃ (0 ~ 50℃)
VIBRATION Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
SAFETY STANDARDS UL508, TUV EN62368-1, EAC TP TC 004 approved;(meet EN60204-1)
WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION Compliance to EN55032 (CISPR32), EN61204-3 Class B, EN61000-3-2,-3, EAC TP TC 020
EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2 (EN50082-2), EN61204-3, heavy industry level, criteria A, EAC TP TC 020
MTBF 486.2K hrs min. MIL-HDBK-217F (25℃)
DIMENSION 32*125.2*102mm (W*H*D)
PACKING 0.51Kg; 28pcs/15.3Kg/1.22CUFT
NOTE

 

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it  still meets EMC directives.
NDR-75-详情_01
NDR-75-详情_02
NDR-75-详情_03
NDR-75-详情_04
NDR-75-详情_05
NDR-75-详情_06
EDR-120-详情_07
EDR-120-详情_08
EDR-120-详情_09
EDR-120-详情_10
EDR-120-详情_11
NDR-75-详情_12

  • Previous:
  • Next:

  • Write your message here and send it to us