page_banner

Products

High definition Variable Voltage Dc Power Supply - 155W Dual Output with Battery Charger (UPS Function) ADD-155 series – Leyu

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Our intention should be to fulfill our consumers by offering golden provider, superior price and superior quality for switch with lock, 220v to 12v switching power supply, 12v 1a power supply, We'll do our greatest to fulfill your specifications and are sincerely searching ahead to developing mutual helpful small business marriage with you!
High definition Variable Voltage Dc Power Supply - 155W Dual Output with Battery Charger (UPS Function) ADD-155 series – Leyu Detail:

155W Dual Output with Battery Charger (UPS Function)  ADD-155 series

Universal AC input / Full range

Built-in active PFC function

Protections: Short circuit / Overload / Over voltage

Battery low protections

Cooling by free air convection

100% full load burn-in test

Fixed switching frequency at PFC 67KHz, PWM 134KHz

2 years warranty

SPECIFICATION
MODEL ADD-155A ADD-155B ADD-155C
OUTPUT
Output number CH1 CH2 CH3 CH1 CH2 CH3 CH1 CH2 CH3
DC voltage 13.8V 5V 13.3V 27.6V 5V 27.1V 54 V 5 V 53.5 V
Rated Current 9.5A 3A 0.5A 4.5A 3A 0.5A 2.3A 3A 0.2A
Current Range 0~10.5A 0~3A ——– 0~5A 0~3A ——— 0~2.5A 0~3A ———
Rated Power 152.75W 152.75W 149.9W
Ripple & Noise 150mVp-p 100mVp-p ——– 200mVp-p 100mVp-p ——- 240mVp-p 100mVp-p ——–
Voltage Adj. Range CH1:12~14.5V CH1:24~29V CH1:48~58V
Voltage Tolerance ±2.0% ±3.0% ——– ±1.0% ±3.0% ——– ±1.0% ±5.0% ——–
Line Regulation ±1.0% ±0.5% ——– ±1.0% ±0.5% ——– ±1.0% ±0.5% ——–
Load Regulation ±1.0% ±2.0% ——– ±1.0% ±2.0% ——– ±1.0% ±2.0% ——–
Setup, Rise Time 1000ms, 90ms/230VAC          2000ms, 90ms/115VAC at full load
Hold Up Time 24ms/230VAC          20ms/115VAC at full load
INPUT
Voltage Range 88~264VAC   47~63Hz; 124~370VDC
AC Current 2.5A/115VAC   1.5A/230VAC
Efficiency 78% 81% 81%
Inrush Current Cold start 20A/115VAC   40A/230VAC
Leakage Current <1mA /240VAC
PROTECTION
Over Load CH1,CH2:105 ~ 135%          CH3:0.51 ~ 0.9A rated output power
Protection type: AC Charging Mode: Hiccup mode, recovers automatically after fault condition is removed UPS Mode: Protected by internal fuse
Over Voltage CH1:15.87~18.63V CH1:31.74~37.26V CH1:62.1~72.9V
Protection type: Hiccup mode, recovers automatically after fault condition is removed
Battery Low 10V±0.8V 19.5V±1.5V 39V±2V
ENVIRONMENT
Working Temp. -10~+60℃ (Refer to “Derating Curve”)
Working Humidity 20~90%RH non-condensing
Storage Temp., Humidity -20~+85℃,10~95%RH
Temp. Coefficient ±0.03%/ ℃(0~50℃ )on CH1 output
Vibration 10~500Hz,2G10min./1cycle,60min.each along X, Y,Z axes
SAFETY &EMC
Safety Standards Design refer to UL60950-1, TUV EN60950-1
Withstand Voltage I/P-O/P:3KVAC   I/P-FG:1.5KVAC   O/P-FG:0.5KVAC
Isolation Resistance I/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC /25℃ /70%RH
EMC Emission Compliance to EN55022(CISPR22) Class B, EN61000-3-2,-3
EMC Immunity Compliance to EN61000-4-2,3,4,5,6,8,11,EN55024,light industry level, criteria A
OTHERS
Dimension 119*11*50mm(L*W*H)
Weight 1Kg
Packing 16pcs/16Kg/0.95CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into final equipment. The final equipment must be re-confirmed that it still meets EMC directives.

Product detail pictures:

High definition Variable Voltage Dc Power Supply - 155W Dual Output with Battery Charger (UPS Function) ADD-155 series  – Leyu detail pictures

High definition Variable Voltage Dc Power Supply - 155W Dual Output with Battery Charger (UPS Function) ADD-155 series  – Leyu detail pictures

High definition Variable Voltage Dc Power Supply - 155W Dual Output with Battery Charger (UPS Function) ADD-155 series  – Leyu detail pictures

High definition Variable Voltage Dc Power Supply - 155W Dual Output with Battery Charger (UPS Function) ADD-155 series  – Leyu detail pictures

High definition Variable Voltage Dc Power Supply - 155W Dual Output with Battery Charger (UPS Function) ADD-155 series  – Leyu detail pictures

High definition Variable Voltage Dc Power Supply - 155W Dual Output with Battery Charger (UPS Function) ADD-155 series  – Leyu detail pictures

High definition Variable Voltage Dc Power Supply - 155W Dual Output with Battery Charger (UPS Function) ADD-155 series  – Leyu detail pictures


Related Product Guide:

With this motto in mind, we've got develop into amongst one of the most technologically innovative, cost-efficient, and price-competitive manufacturers for High definition Variable Voltage Dc Power Supply - 155W Dual Output with Battery Charger (UPS Function) ADD-155 series – Leyu , The product will supply to all over the world, such as: Malaysia, Provence, New Zealand, We are proud to supply our products to every auto fan all around the world with our flexible, fast efficient services and strictest quality control standard which has always approved and praised by customers.
  • The company can think what our think, the urgency of urgency to act in the interests of our position, can be said this is a responsible company, we had a happy cooperation!
    5 Stars By Hilda from Bangkok - 2017.10.25 15:53
    Superb technology, perfect after-sales service and efficient work efficiency, we think this is our best choice.
    5 Stars By Emma from Jakarta - 2017.09.09 10:18
    Write your message here and send it to us