The input and output are completely isolated, safe and reliable
Wide input voltage range for stable operation over a wide range
Light weight, small size, shockproof, high efficiency, low interference, safe and reliable
With regulation, steady flow, continuous regulation, over-voltage, over-current, short-circuit, and over-temperature protection
Safe and reliable performance, easy to use, easy to operate, high stability, low ripple, wide range of applications
Applications: electric vehicles, DC air conditioners, railways, locomotives, photovoltaics, AGVs, mobile charging stations, etc.
100WSingle Output DC-DC Converter SD-100series:
2:1 wide input range
Protections: Shortcircuit / Overload / Over voltage
1500VAC I/O isolation
Built-in EMI filter, lowripple noise
100% full load burn-intest
Fixed switchingfrequency at 83 KHz
24V and 48V inputvoltage design refer to LVD
Low costHigh reliability
2 years warranty
SPECIFICATION | ||||||||||||||||
OUTPUT | ||||||||||||||||
Model |
SD-100A-5 |
SD-100B-5 |
SD-100D-5 |
SD-100B-12 |
SD-100C-12 |
SD-100D-12 |
SD-100B-24 |
SD-100C-24 |
SD-100D-24 |
SD-100B-48 |
SD-100C-48 |
SD-100D-48 |
||||
DC Voltage |
5V |
12V |
24V |
48V |
||||||||||||
Rated Current |
20A |
8.5A |
4.2A |
2.1A |
||||||||||||
Current Range |
0~20A |
0~8.5A |
0~4.2A |
0-2.1A |
||||||||||||
Rated Power |
100W |
102W |
100.8W |
100.8W |
||||||||||||
Ripple&Noise |
100mVp-p |
120mVp-p |
150mVp-p |
150mVp-p |
||||||||||||
Voltage Adj.Range |
4.5~5.5VDC |
11~16VDC |
23~30VDC |
43.2-52.8VDC |
||||||||||||
Voltage Tolerance |
±2.0% |
±1.0% |
±1.0% |
±1.0% |
||||||||||||
Line Regulation |
±0.5% |
±0.3% |
±0.2% |
±0.2% |
||||||||||||
Load Regulation |
±0.5% |
±0.3% |
±0.2% |
±0.2% |
||||||||||||
Setup, Rise Time | 2s,50ms(only D mode) at full load | |||||||||||||||
Hold Up Time | 20ms(only D mode) at full load | |||||||||||||||
INPUT | ||||||||||||||||
Voltage Range | A:9.2~18VDCB:19~36VDC C:36~72VDC D:72~144VDC or 85~132VAC | |||||||||||||||
Efficiency |
74% |
75% |
76% |
75% |
77% |
80% |
78% |
81% |
83% |
78% |
81% |
83% |
||||
DC Current |
4.8A/18V |
2.4A/24V |
1.8A/96V |
4.8A/24V |
2.4A/48V |
1.8A/96V |
4.8A/24V |
2.4A/48V |
1.8A/96V |
4.8A/24V |
2.4A/48V |
1.8A/96V |
||||
Inrush Current | D:18A/96VDC | |||||||||||||||
Leakage Current | <0.75mA/120VAC(SD-100D) | |||||||||||||||
PROTECTION | ||||||||||||||||
Over Load | 105~135% rated output power | |||||||||||||||
Protection type: Hiccup mode,recovers automatically after fault condition is removed | ||||||||||||||||
Over Voltage |
5.75~6.75V/10%load |
16.8~20V/10%load |
31.5~37.5V/10%load |
60.2-79.2/10%load |
||||||||||||
Protection type:Hiccup mode,recovers automatically after fault condition is removed | ||||||||||||||||
ENVIRONMENT | ||||||||||||||||
Working Temp. | -10~+60℃ (Refer to“Derating Curve”) | |||||||||||||||
Working Humidity | 20~90%RH non-condensing | |||||||||||||||
Storage Temp.,Humidity | -20~+85℃,10~95%RH | |||||||||||||||
Temp.Coefficient | ±0.03%/℃ (0~50℃) | |||||||||||||||
Vibration | 10~500Hz,2G 10min./1cycle,60min.each along X, Y, Z axes | |||||||||||||||
SAFETY &EMC | ||||||||||||||||
Safety Standards | IEC60950-1CB approved by TUV(for D type only) | |||||||||||||||
Withstand Voltage | I/P-O/P:1.5KVAC I/P-FG:2.0KVAC O/P-FG:0.5KVAC | |||||||||||||||
Isolation Resistance | I/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC /25℃ /70%RH | |||||||||||||||
EMC Emission | Compliance to EN55022(CISPR22) Class B | |||||||||||||||
EMC Immunity | Compliance to EN61000-4-2,3,4,6,8,light industry level,criteria A | |||||||||||||||
OTHERS | ||||||||||||||||
Dimension | 199*98*38mm(L*W*H) | |||||||||||||||
Weight | 0.55Kg | |||||||||||||||
Packing | 30pcs/16.5Kg | |||||||||||||||
NOTE | ||||||||||||||||
1. All parameters NOT specially mentioned are measured at 24,48,96VDC input, rated load and 25℃ of ambient temperature.2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.3. Tolerance : includes set up tolerance, line regulation and load regulation.4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. | ||||||||||||||||
1. Small quantity orders acceptable;
2. We will choose the most suitable shipping way for you and inform you the cost advance, decision will be made by you;
3. We have larger stocks and this support us can make a very prompt shipping;
4. To assure you the maximum comfort and satisfaction, we accept pay via T/T, Paypal, Western Union;
5. Price could be negotiated for more and large quantity;
6. Your enquiry will be quickly response, we will choose the most suitable products and quote the most competitive price for you.