page_banner

Products

100W Single Output Switching Power Supply NES-100 series

Short Description:

Protections: Short circuit / Overload / Over voltage

Cooling by free air convection

LED indicator for power on

100% full load burn-in test

2 years warranty


Product Detail

Product Tags

Features

100W Single Output Switching Power Supply NES-100 series

Protections: Short circuit / Overload / Over voltage

Cooling by free air convection

LED indicator for power on

100% full load burn-in test

2 years warranty

Specifications

SPECIFICATION  
OUTPUT  
Model NES-100-5 NES-100-7.5 NES-100-9 NES-100-12 NES-100-15 NES-100-24 NES-100-48
DC Voltage 5V 7.5V 9V 12V 15V 24V 48V
Rated Current 20A 13.6A 11.2A 8.5A 7A 4.5A 2.3A
Current Range 0~20A 0~13.6A 0~11.2A 0~8.5A 0~7A 0~4.5A 0~2.3A
Rated Power 100W 102W 100.8W 102W 105W 108W 110.4W
Ripple & Noise 80mVp-p 120mVp-p 120mVp-p 120mVp-p 120mVp-p 120mVp-p 150mVp-p
Voltage Adj. Range 4.75 ~ 7.13 ~ 8.3V 8.55 ~ 9.9V 11.4 ~ 13.2V 14.25 ~ 16.5V 22.8 ~ 26.4V 45.6 ~ 52.8V
5.5V
Voltage Tolerance ±2.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
Line Regulation ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
Load Regulation ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
Setup, Rise Time 1000ms, 20ms/230VAC   1000ms, 20ms/115VAC at full load
Hold Up Time 30ms/230VAC   25ms/115VAC at full load
INPUT  
Voltage Range 85 ~ 132VAC / 176 ~ 264VAC selected by switch   248 ~ 373VDC
Frequency Range 47 ~ 63Hz
Efficiency 80% 81% 83% 84% 86% 86%
AC Current 2A/115VAC   1.2A/230VAC
Inrush Current Cold Start 45A
Leakage Current <2mA / 240VAC
PROTECTION  
Over Load  110 ~ 150% rated output power
Protection type: Hiccup mode, recovers automatically after fault condition is removed
Over Voltage  5.75 ~ 6.75V 10.4 ~ 12.2V 13.8 ~ 16.2V 17.25 ~ 20.25V 27.6 ~ 32.4V 55.2 ~ 64.8V
Protection type: Hiccup mode, recovers automatically after fault condition is removed
ENVIRONMENT  
Working Temp. -20 ~ +60℃ (Refer to “Derating Curve”)
Working Humidity 20 ~ 90% RH non-condensing
Storage Temp., Humidity -40 ~ +85℃, 10 ~ 95% RH
Temp. Coefficient ±0.03%/℃ (0 ~ 50℃)
Vibration 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC  
Safety Standards Design refer to UL60950-1, CB(IEC60950-1),CCC GB4943
Withstand Voltage I/P-O/P:3KVAC   I/P-FG:2KVAC   O/P-FG:0.5KVAC
Isolation Resistance I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃ / 70% RH
EMC Emission Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
EMC Immunity Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-1, light industry level, criteria A
OTHERS  
Dimension 159*97*38mm (L*W*H)
Weight 0.55Kg
Packing 30pcs/carton/17.5kg/0.97CUFT
NOTE  
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.

"

"

"

"

"

"