Sticking for the basic principle of “Super Top quality, Satisfactory service” ,We’ve been striving to be an excellent business enterprise partner of you for Hot-selling China Customized 24V 60W Waterproof single output switching for Power Supply, We warmly welcome good friends from all walks of life to cooperate with us.
Sticking for the basic principle of “Super Top quality, Satisfactory service” ,We’ve been striving to be an excellent business enterprise partner of you for , We have now 48 provincial agencies in the country. We also have stable cooperation with several international trading companies. They place order with us and export solutions to other countries. We expect to cooperate with you to develop a larger market.
1. The input voltage of the waterproof switching power supply should be selected according to the design of the circuit. Generally, there are two kinds of input voltage: 220 volts and 110 volts. If you choose improperly, it will damage the switching power supply.
2. Do not connect the ground wire and neutral wire end of the output voltage wiring wrongly, and make sure that the grounding is reliable.
3. After the switching power supply is installed, it is necessary to conduct a power-on trial operation, check the condition of each part, and ensure that it can be powered on after it is normal.
60W Waterproof Single Output Switching Power Supply LPV-60 series
Constant voltage design
Universal AC input/Full range
Withstand 300VAC surge input for 5 seconds
Protections: short circuit/ over load/ over voltage
Cooling by free air convection
Small and compact size
Fully encapsulated with IP67 level
Fully isolated plastic case
Class II power unit, no FG
Class 2 power unit
Pass LPS
Suitable for LED lighting and moving sign applications
100% full load burn-in test
Low cost, high reliability
2 year warranty
SPECIFICATIONS | ||||||
OUTPUT | ||||||
Model |
LPV-60-5 |
LPV-60-12 |
LPV-60-15 |
LPV-60-24 |
LPV-60-36 |
LPV-60-48 |
DC Voltage |
5V |
12V |
15V |
24V |
36V |
48V |
Rated Current |
8A |
5A |
4A |
2.5A |
1.67A |
1.25A |
Current Range |
0-8A |
0-5A |
0-4A |
0-2.5A |
0-1.67A |
0-1.25A |
Rated Power |
40W |
60W |
60W |
60W |
60W |
60W |
Ripple & Noise |
80mVp-p |
120mVp-p |
120mVp-p |
150mVp-p |
150mVp-p |
150mVp-p |
Voltage Tolerance |
±8% |
±5% |
||||
Line Regulation |
±1% |
|||||
Load Regulation |
±6% |
±2% |
||||
Setup, Rise Time | 500ms, 20ms/230VAC 500ms, 20ms/115VAC at full load(for 5-36V)500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load(for 48V) | |||||
Hold Up Time | 50ms/230VAC 16ms/115VAC at full load | |||||
INPUT | ||||||
Voltage Range |
90~264VAC 47-63Hz; 127~370VDC |
|||||
AC Current | 1.2A/115V 1A/230V | |||||
Efficiency |
76% |
83% |
83% |
86% |
86% |
86% |
Inrush Current | Cold Start 60A at 230VAC | |||||
Leakage Current | 0.25mA/240VAC | |||||
PROTECTION | ||||||
Over Load | 110-150% rated output power | |||||
Protection type: Hiccup mode, recovers automatically after fault condition is removed | ||||||
Over Voltage |
5.75-6.75V |
13.8-16.2V |
17.25-20.25V |
27.6-32.4V |
41.4-48.6V |
55.2-64.8V |
Protection type: Shut down o/p voltage, re-power on to recover | ||||||
ENVIRONMENT | ||||||
Working Temp.Humidity | -30 ~ +70℃ (Refer to “Derating Curve”) | |||||
Storage Temp.Humidity | -40℃~+80℃; 10%~95%RH | |||||
Temp.Coefficient | ±0.03%/℃(0~50℃) | |||||
Vibration | 10~500Hz,2G 10min,/1cycle,period for 60min,each along X,Y,Z axes | |||||
SAFETY | ||||||
Withstand Voltage | I/P-O/P:3KVAC | |||||
Isolation Resistance | I/P-O/P>100M Ohms / 500VDC / 25℃ / 70% RH | |||||
STANDARD | ||||||
Safety Standard | UL879(expect for LPV-60-5), UL1310(expect for LPV-60-5), CSA C22.2 No.207-M91(expect for LPV-60-5, LPV-60-48), IP67, IEC60950-1:2005+A2:2013 approved; design refer to TUV EN60950-1 | |||||
EMC Standard | EN61000-4-2,3,4,5,6,8,11,EN55024,light industry level, criteria A | |||||
OTHERS | ||||||
Dimension | 162.5*42.5*32mm(L*W*H) | |||||
Weight | 0.4kg;32pcs/13.8kg/0.56CUFT | |||||
NOTE | ||||||
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.3. Tolerance: includes set up tolerance, line regulation and load regulation.
4. Derating may not be needed under low input voltage. Please check the static characteristics for more details. |
Sticking for the basic principle of “Super Top quality, Satisfactory service” ,We’ve been striving to be an excellent business enterprise partner of you for Hot-selling China Customized 60W Waterproof single output switching for Power Supply, We warmly welcome good friends from all walks of life to cooperate with us.
We also have stable cooperation with several international trading companies. They place order with us and export solutions to other countries. We expect to cooperate with you to develop a larger market.