page_banner

Products

600W Single Output with Parallel Function SCN-600 series

Short Description:

·High reliability, low ripple

·Universal AC input/ full range

·Protections: Short circuit/ Over load/ Over voltage/ Over temperature

·Built-in ON-OFF control and remote sense function

·With parallel function

·Can adjust from 40%~100% output voltage by external control 2-5V

·Forced air cooling by built-in DC fan


Product Detail

Product Tags

Features

600W Single Output with Parallel Function SCN-600 series

·High reliability, low ripple

·Universal AC input/ full range

·Protections: Short circuit/ Over load/ Over voltage/ Over temperature

·Built-in ON-OFF control and remote sense function

·With parallel function

·Can adjust from 40%~100% output voltage by external control 2-5V

·Forced air cooling by built-in DC fan

Specifications

SPECIFICATIONS
OUTPUT  
MODEL

SCN-600-12

SCN-600-15

SCN-600-24

SCN-600-48

DC Voltage

12V

15V

24V

48V

Rated Current

50A

40A

25A

12.5A

Current Range

0-50A

0-40A

0-25A

0-12.5A

Rated Power

600W

600W

600W

600W

Ripple & Noise

120mVp-p

150mVp-p

240mVp-p

480mVp-p

Voltage Adj. Range ±5%; Can adjust from 40%~100% output voltage by external control 2-5V
Voltage Tolerance

±1%

±1%

±1%

±1%

Setup, Rise, Hold Up Time 800ms, 50ms, 16ms at full load
INPUT  
Voltage Range 90~130VAC/180~260VAC selected by switch   47~63Hz; 260~370VDC
AC Current 11A/115VAC   7.0A/230VAC
Efficiency

80%

81%

85%

87%

Inrush Current 60A/230V
Leakage Current 3.5mA/240VAC
PROTECTION  
Over Load 110%~135%
Protection: Protection:Current limiting, delay shut down o/p voltage, re-power on to recover
Over Voltage 110%~135%
Protection type: Shut down o/p voltage, re-power on to recover
Over Temp TSW1(Power transistor) When temp. >100℃, shut down o/p voltage, re-power on to recover
ENVIRONMENT  
Working Temp., Humidity -10℃~+65℃; 20%~90%RH
Storage Temp., Humidity -20℃~+85℃; 10%~95%RH
Vibration 10~200Hz, 2G 10min./1cycle, period for 60min, each along X, Y, Z axes
SAFETY  
Withstand Voltage I/P-O/P, I/P-FG:1500VAC
Isolation Resistance I/P-O/P, I/P-FG, >100M Ohms / 500VDC
STANDARD  
Safety Standard Design refer to UL1950,CSA22.2,IEC60950
EMC Standard Design refer to FCC Part 15 Class A
OTHERS  
Dimension 291*132*68mm(L*W*H)
Weight 2.57Kg
Packing 6pcs/15.42kg/CARTON
NOTE  
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1μ & 47μ parallel capacitor.

3.Tolerance: includes set up tolerance, line regulation and load regulation.

4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.