page_banner

Products

75W Single Output Industrial DIN Rail Power Supply EDR-75 series

Short Description:

Universal AC input/ full range

Protections: Short circuit/ Over load/ Over voltage/ Over temperature

Cooling by free air convection

Can be installed on DIN rail TS-35/7.5 or 15

LED indicator for power on

100% full load burn-in test

Fixed switching frequency at 67KHz

2 year warranty


Product Detail

Product Tags

Features

75W Single Output Industrial DIN Rail Power Supply         EDR-75 series

Universal AC input/ full range

Protections: Short circuit/ Over load/ Over voltage/ Over temperature

Cooling by free air convection

Can be installed on DIN rail TS-35/7.5 or 15

LED indicator for power on

100% full load burn-in test

Fixed switching frequency at 67KHz

2 year warranty

Specifications

SPECIFICATIONS
OUTPUT  
Model

EDR-75-12

EDR-75-24

EDR-75-48

DC Voltage

12V

24V

48V

Rated Current

6.3A

3.2A

1.6A

Current Range

0-6.3A

0-3.2A

0-1.6A

Rated Power

75.6W

76.8W

76.8W

Ripple & Noise

100mVp-p

120mVp-p

150mVp-p

Voltage Adj. Range

12-14V

24-28V

48-53V

Voltage Tolerance

±2%

±1%

±1%

Setup, Rise Time 1000ms,60ms/230VAC   1800ms,60ms/115VAC at full load
Hold Up Time 60ms/230VAC   12ms/115VAC at full load
   
INPUT  
Voltage Range 85~264VAC   47~63 Hz; 120~370VDC
AC Current 1.6A/115V   0.96A/230V
Efficiency

83%

85%

86%

Inrush Current Cold start 20A/115VAC   40A/230VAC
Leakage Current <1mA/240VAC
   
PROTECTION  
Over Load 105%~150%
Protection type: Constant current limiting, recovers automatically after fault condition is removed
Over Voltage 120%~140%
Protection type: Shut down o/p voltage, re-power on to recover
Over Temp. TSW1≥85℃±5℃
Protection type: Shut down o/p voltage, recovers automatically after temperature goes down
   
ENVIRONMENT  
Working Temp., Humidity -10℃~+60℃; 20%~90%RH
Storage Temp., Humidity -20℃~+85℃; 10%~95%RH
Vibration 10~500Hz, 2G 10min./1cycle, period for 60min, each along X, Y, Z axes
   
SAFETY  
Withstand Voltage I/P-O/P: 3KVAC   I/P-FG: 1.5KVAC   O/P-FG: 0.5KVAC
Isolation Resistance I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC
   
STANDARD  
Safety Standard Design refer to UL508,TUV EN60950-1
EMC Standard EN55011,EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11,ENV50204,EN55024,EN61000-6-2
   
OTHERS  
Dimension 32.5*125.2*102mm(L*W*H)
Weight 0.45Kg
Packing 30pcs/16Kg/1.1CUFT
   
NOTE  
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.

2.Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1μ & 47μ parallel capacitor.

3.Tolerance: includes set up tolerance, line regulation and load regulation.

4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.